Operation
| Brackett
Brieden Backflush Filter during backflushing operation
|
- Filter body
- Filter Elements
- Pressure Gauge
- Differential Pressure Switch
- Drive
- Revolving Turntable
- Backflush pipe
- Backflush Valve
- Turntable Seal
- Access Cover
- Automatic Vent
|
 |
The fluid to be filtered flows
through the inlet connection into the lower half of
the filter body (1), upwards through the turntable (6)
into the inside of the filter elements (2).
Flowing from the inside to the outside
of the debris filter elements, the solids are retained on the
inside of the filter elements. The clean fluid
then leaves the filter body through the upper outlet
connection.
The requirement to backflush is initiated
by timer of rising differential. When the signal
to backflush is given, one complete backflush cycle
would be performed automatically.
Backflushing is achieved without interruption
to the flow through the debris filter. The drive (5) rotates
the turntable (6) and the backflush valve is opened
(8). Each element in turn moves across the backflush
outlet pipe (7). The difference in pressure between
the inside of the filter body and atmospheric pressure
produces a reverse flow through the filter elements
thereby removing the retained debris.
Design and Construction of Brieden Automatic Backflush Filter
The filter body design is based on BS5500 for
pressure vessels as a minimum standard and can
be designed and manufactured to specific requirements
with third party verification. The standard construction
is either carbon steel with epoxy or rubber lining,
or Stainless steel. Filter bodies can be
fabricated in other materials if required.
Selecting the correct filter
The choice of debris filter is dependant on the site operating
conditions and the filtration requirements of the system.
The following factors should be taken into consideration.
- Type of fluid to be filtered
- Flow rate
- Level of filtration
- Volume of solids to be removed
- System pressure
The following tables give an indication
of the Brieden Automatic Backflush Filters capacities
based on typical cooling water applications with solids
loading of 50 to 100 mg/l. For larger capacity
filters, other applications or for further information
see the contacts
section for contact information.
| V-Gap
Wedge Wire Elements |
| Filter Type |
Flange DN
max |
Capacity
of Filtration (in m3/h) at Dp approx 0.15
bar
Fineness of filtration |
| 50
micron |
75
micron |
100
micron |
150
micron |
200
micron |
300
micron |
| BRF-S
3304 |
80 |
10 |
18 |
34 |
44 |
60 |
60 |
| BRF-S 3307 |
125 |
20 |
34 |
64 |
83 |
120 |
150 |
| BRF-S
3310 |
150 |
30 |
55 |
100 |
140 |
180 |
200 |
| BRF-S 3313 |
175 |
40 |
70 |
120 |
180 |
230 |
250 |
| BRF-S
3316 |
200 |
65 |
115 |
170 |
270 |
360 |
360 |
| BRF-S 3319 |
250 |
90 |
160 |
250 |
360 |
540 |
600 |
| BRF-S
3322 |
300 |
120 |
210 |
350 |
500 |
700 |
900 |
| BRF-S 3325 |
350 |
170 |
300 |
450 |
680 |
1000 |
1200 |
| BRF-S
3328 |
400 |
220 |
390 |
600 |
880 |
1250 |
1500 |
| BRF-S 3331 |
400 |
280 |
500 |
740 |
1100 |
1500 |
1500 |
| BRF-S
3337 |
500 |
380 |
680 |
1100 |
1600 |
2000 |
2000 |
| BRF-S 3340 |
600 |
520 |
940 |
1600 |
2400 |
3200 |
3200 |
| BRF-S 3343 |
700 |
700 |
1250 |
2000 |
3200 |
4100 |
4100 |
| BRF-S 3346 |
800 |
930 |
1660 |
2600 |
4200 |
5400 |
5400 |
| Breathing
Elements |
| Filter Type |
Flange DN max |
Capacity of Filtration
(in m3/h) at Dp approx 0.15 bar
Fineness of filtration |
| 50 micron |
75 micron |
100 micron |
150 micron |
200 micron |
300 micron |
| BRF-50-3 |
80 |
10 |
18 |
26 |
42 |
60 |
60 |
| BRF-50-4 |
100 |
13 |
24 |
26 |
54 |
80 |
100 |
| BRF-50-5 |
125 |
22 |
40 |
60 |
90 |
120 |
150 |
| BRF-50-7 |
150 |
31 |
52 |
80 |
120 |
150 |
200 |
| BRF-50-9 |
150 |
40 |
70 |
120 |
160 |
200 |
200 |
| BRF-50-11 |
175 |
48 |
88 |
140 |
200 |
260 |
260 |
| BRF-80-6 |
200 |
56 |
105 |
160 |
240 |
360 |
360 |
| BRF-80-7 |
250 |
66 |
125 |
186 |
280 |
400 |
520 |
| BRF-80-9 |
250 |
85 |
160 |
240 |
360 |
540 |
600 |
| BRF-80-12 |
300 |
115 |
215 |
330 |
480 |
720 |
900 |
| BRF-80-15 |
350 |
142 |
270 |
410 |
600 |
900 |
1150 |
| BRF-115-9 |
350 |
160 |
300 |
470 |
680 |
1000 |
1200 |
| BRF-115-12 |
400 |
210 |
400 |
630 |
900 |
1350 |
1500 |
| BRF-115-15 |
500 |
270 |
510 |
790 |
1130 |
1700 |
2000 |
| BRF-165-12 |
600 |
380 |
720 |
1080 |
1600 |
2400 |
3150 |
| BRF-165-18 |
700 |
570 |
1080 |
1620 |
2400 |
3600 |
4100 |
| BRF-165-24 |
900 |
760 |
1450 |
2170 |
3230 |
4800 |
6300 |
| BRF-165-30 |
1000 |
960 |
1800 |
2720 |
4030 |
6000 |
8000 |
|